967 research outputs found

    On the Use of Electrooculogram for Efficient Human Computer Interfaces

    Get PDF
    The aim of this study is to present electrooculogram signals that can be used for human computer interface efficiently. Establishing an efficient alternative channel for communication without overt speech and hand movements is important to increase the quality of life for patients suffering from Amyotrophic Lateral Sclerosis or other illnesses that prevent correct limb and facial muscular responses. We have made several experiments to compare the P300-based BCI speller and EOG-based new system. A five-letter word can be written on average in 25 seconds and in 105 seconds with the EEG-based device. Giving message such as “clean-up” could be performed in 3 seconds with the new system. The new system is more efficient than P300-based BCI system in terms of accuracy, speed, applicability, and cost efficiency. Using EOG signals, it is possible to improve the communication abilities of those patients who can move their eyes

    Frontal brain asymmetries as effective parameters to assess the quality of audiovisual stimuli perception in adult and young cochlear implant users

    Get PDF
    How is music perceived by cochlear implant (CI) users? This question arises as "the next step" given the impressive performance obtained by these patients in language perception. Furthermore, how can music perception be evaluated beyond self-report rating, in order to obtain measurable data? To address this question, estimation of the frontal electroencephalographic (EEG) alpha activity imbalance, acquired through a 19-channel EEG cap, appears to be a suitable instrument to measure the approach/withdrawal (AW index) reaction to external stimuli. Specifically, a greater value of AW indicates an increased propensity to stimulus approach, and vice versa a lower one a tendency to withdraw from the stimulus. Additionally, due to prelingually and postlingually deafened pathology acquisition, children and adults, respectively, would probably differ in music perception. The aim of the present study was to investigate children and adult CI users, in unilateral (UCI) and bilateral (BCI) implantation conditions, during three experimental situations of music exposure (normal, distorted and mute). Additionally, a study of functional connectivity patterns within cerebral networks was performed to investigate functioning patterns in different experimental populations. As a general result, congruency among patterns between BCI patients and control (CTRL) subjects was seen, characterised by lowest values for the distorted condition (vs. normal and mute conditions) in the AW index and in the connectivity analysis. Additionally, the normal and distorted conditions were significantly different in CI and CTRL adults, and in CTRL children, but not in CI children. These results suggest a higher capacity of discrimination and approach motivation towards normal music in CTRL and BCI subjects, but not for UCI patients. Therefore, for perception of music CTRL and BCI participants appear more similar than UCI subjects, as estimated by measurable and not self-reported parameters

    Joint analysis of eye blinks and brain activity to investigate attentional demand during a visual search task

    Get PDF
    In several fields, the need for a joint analysis of brain activity and eye activity to investigate the association between brain mechanisms and manifest behavior has been felt. In this work, two levels of attentional demand, elicited through a conjunction search task, have been modelled in terms of eye blinks, brain activity, and brain network features. Moreover, the association between endogenous neural mechanisms underlying attentional demand and eye blinks, without imposing a time-locked structure to the analysis, has been investigated. The analysis revealed statistically significant spatial and spectral modulations of the recorded brain activity according to the different levels of attentional demand, and a significant reduction in the number of eye blinks when a higher amount of attentional investment was required. Besides, the integration of information coming from high-density electroencephalography (EEG), brain source localization, and connectivity estimation allowed us to merge spectral and causal information between brain areas, characterizing a comprehensive model of neurophysiological processes behind attentional demand. The analysis of the association between eye and brain-related parameters revealed a statistically significant high correlation (R > 0.7) of eye blink rate with anterofrontal brain activity at 8 Hz, centroparietal brain activity at 12 Hz, and a significant moderate correlation with the participation of right Intra Parietal Sulcus in alpha band (R = -0.62). Due to these findings, this work suggests the possibility of using eye blinks measured from one sensor placed on the forehead as an unobtrusive measure correlating with neural mechanisms underpinning attentional demand

    Human brain distinctiveness based on EEG spectral coherence connectivity

    Full text link
    The use of EEG biometrics, for the purpose of automatic people recognition, has received increasing attention in the recent years. Most of current analysis rely on the extraction of features characterizing the activity of single brain regions, like power-spectrum estimates, thus neglecting possible temporal dependencies between the generated EEG signals. However, important physiological information can be extracted from the way different brain regions are functionally coupled. In this study, we propose a novel approach that fuses spectral coherencebased connectivity between different brain regions as a possibly viable biometric feature. The proposed approach is tested on a large dataset of subjects (N=108) during eyes-closed (EC) and eyes-open (EO) resting state conditions. The obtained recognition performances show that using brain connectivity leads to higher distinctiveness with respect to power-spectrum measurements, in both the experimental conditions. Notably, a 100% recognition accuracy is obtained in EC and EO when integrating functional connectivity between regions in the frontal lobe, while a lower 97.41% is obtained in EC (96.26% in EO) when fusing power spectrum information from centro-parietal regions. Taken together, these results suggest that functional connectivity patterns represent effective features for improving EEG-based biometric systems.Comment: Key words: EEG, Resting state, Biometrics, Spectral coherence, Match score fusio

    Defecting or not defecting: how to "read" human behavior during cooperative games by EEG measurements

    Get PDF
    Understanding the neural mechanisms responsible for human social interactions is difficult, since the brain activities of two or more individuals have to be examined simultaneously and correlated with the observed social patterns. We introduce the concept of hyper-brain network, a connectivity pattern representing at once the information flow among the cortical regions of a single brain as well as the relations among the areas of two distinct brains. Graph analysis of hyper-brain networks constructed from the EEG scanning of 26 couples of individuals playing the Iterated Prisoner's Dilemma reveals the possibility to predict non-cooperative interactions during the decision-making phase. The hyper-brain networks of two-defector couples have significantly less inter-brain links and overall higher modularity - i.e. the tendency to form two separate subgraphs - than couples playing cooperative or tit-for-tat strategies. The decision to defect can be "read" in advance by evaluating the changes of connectivity pattern in the hyper-brain network

    Neurophysiological vigilance characterisation and assessment: Laboratory and realistic validations involving professional air traffic controllers

    Get PDF
    Vigilance degradation usually causes significant performance decrement. It is also considered the major factor causing the out-of-the-loop phenomenon (OOTL) occurrence. OOTL is strongly related to a high level of automation in operative contexts such as the Air Traffic Management (ATM), and it could lead to a negative impact on the Air Traffic Controllers’ (ATCOs) engagement. As a consequence, being able to monitor the ATCOs’ vigilance would be very important to prevent risky situations. In this context, the present study aimed to characterise and assess the vigilance level by using electroencephalographic (EEG) measures. The first study, involving 13 participants in laboratory settings allowed to find out the neurophysiological features mostly related to vigilance decrements. Those results were also confirmed under realistic ATM settings recruiting 10 professional ATCOs. The results demonstrated that (i) there was a significant performance decrement related to vigilance reduction; (ii) there were no substantial differences between the identified neurophysiological features in controlled and ecological settings, and the EEG-channel configuration defined in laboratory was able to discriminate and classify vigilance changes in ATCOs’ vigilance with high accuracy (up to 84%); (iii) the derived two EEG-channel configuration was able to assess vigilance variations reporting only slight accuracy reduction

    Drop-in analysis of an internal heat exchanger in a vapour compression system using R1234ze(E) and R450A as alternatives for R134a

    Full text link
    The IHX (internal heat exchanger) is introduced in some refrigeration systems in order to achieve higher energy performances. Results obtained vary greatly depending on the refrigerant used and working conditions. This paper describes a drop-in analysis of IHX effects on the performance of a vapour compression system using R1234ze(E) and R450A (R134a/R1234ze(E) commercial mixture) as R134a low-GWP replacements. The tests were carried out in a completely monitored vapour compression system varying the condensing and evaporating temperature, with and without a counter-current flow tube-in-tube IHX. Because the cooling capacity rises and the power consumption remains similar, the conclusion is that the IHX has a positive influence on the energy efficiency for all refrigerants tested. The COP (coefficient of performance) gain using R1234ze(E) is the highest observed (overcomes the R134a COP for the same conditions). The R1234ze(E) and R450A discharge temperature increments are lower than those of R134a so does not reach dangerous values and the IHX pressure drops are also below than that of R134a.The authors thankfully acknowledge "Ministerio de Educacion, Cultura y Deporte - Gobierno de Espana" (Grant number FPU12/02841) for supporting this work through "Becas y Contratos de Formacion de Profesorado Universitario del Programa Nacional de Formacion de Recursos Humanos de Investigacion del ejercicio 2012".Mota Babiloni, A.; Navarro Esbrí, J.; Barragán Cervera, Á.; Moles, F.; Peris, B. (2015). Drop-in analysis of an internal heat exchanger in a vapour compression system using R1234ze(E) and R450A as alternatives for R134a. Energy. 90:1636-1644. https://doi.org/10.1016/j.energy.2015.06.133S163616449

    A Comprehensive Energy Model for an Optimal Design of a Hybrid Refrigerated Van

    Get PDF
    The path towards decarbonization requires a progressive adaptation of all refrigeration systems, but only stationary ones have been intensely studied to improve their environmental performance. However, refrigerated transport is vital in the cold chain and must be considered in the green transition. In this paper, we propose a model for a hybrid refrigerated van that includes photovoltaic panels and electric batteries to decrease total greenhouse gas emissions from the engine. Thermal, electrical, and battery sub-models are considered and integrated into the comprehensive hybrid solar-powered refrigerated van model. Different technologies are compared, including lithium and lead-acid batteries and three different types of photovoltaic panels. The model was validated regarding van fuel consumption, showing a 4% deviation. Single and multiple delivery scenarios are considered to assess the energy, economic, and environmental benefits. Monthly CO2,e emissions could be reduced by 20% compared to a standard refrigerated van. Despite the environmental benefits provided by this sustainable solution, the payback period is still too long (above 20 years) because of the necessary investment to adapt the vehicle and considering fuel and electricity prices currently
    corecore